DAIKIN CS 10.0kW Standard Inverter Cassette System

$4,668.00

DAIKIN FCA100CVMASBHD-1P

10.0kW Standard Inverter Reverse Cycle Cassette System | 1 Phase

Includes Indoor FCA100CVMA | Outdoor RZAC100C2V1

Fascia – BYCQ125EAK | Controller – BRC1E63

10.0 kW Cooling | 11.2 kW Heating

3.74 Star Energy Rating

SKU: FCA100CVMASBHD-1P Categories: ,

SPECIFICATIONS

Indoor Unit FCA100CVMA
Outdoor Unit RZAC100C2V1
Power Supply ø / V / Hz 1 Phase, 220-240V, 50 Hz
Cooling Capacity Rated (Min – Max) kW 10.0 (3.2 – 11.2)
Heating Capacity Rated (Min – Max) kW 11.2 (3.5 – 12.5)
Power Consumption Cooling kW 2.67
Heating kW 2.74
Enery Efficiency EER kW 3.74
COP kW 4.09
Indoor Unit Colour Unit
Decoration Panel Fresh White
Airflow Rate (H / HM / M / ML / L) L/s 575 / 517 / 458 / 400 / 333
m³/min 34.5 / 31.0 / 27.5 / 24.0 / 20.0
Sound Pressure Level (H / HM / M / ML / L) dB(A) 45.0 / 42.0 / 39.0 / 36.5 / 34.0
Dimensions (HxWxD) Unit mm 298 x 840 x 840
Decoration Panel mm 50 x 950 x 950
Machine Weight Unit kg 26
Decoration Panel kg 5.5
Certified Operation Range Cooling °CWB 14 to 25
Heating °CDB 15 to 27
Outdoor Unit Colour Ivory white
Compresser Type Hermetically sealed swing type
Motor output kW 2.4
Refrigerant Charge (R410a) kg 2.6 (charged for 30m)
Sound Level Cooling / Heating dB(A) 52 / 54
Night quiet mode dB(A) 48
Sound Power Level (H/L) dB(A) 71
Dimensions (HxWxD) mm 990 x 940 x 320
Machine Weight kg 69
Certified Operation range Cooling °CDB -5 to 46
Heating °CWB -15 to 15.5
Piping Connections Liquid (Flare) mm ø9.5
Gas (Flare) mm ø15.9
Drain Indoor Unit mm I.D. ø25 x O.D ø32
Outdoor Unit mm ø26.0 (Hole)
Refrigerant R32
Max, interunit piping length m 50 (Equivalent length 70)
Max. Installation level difference m 30
Heat insulation Both liquid and gas piping

FEATURES

Cassette air conditioner with 360° uniform airflow sets the standard.

Circulation Airflow

Cools the entire room to deliver comfort that never feels cold.
Effectiveness may differ according to room conditions, room size, and distance to walls.

Individual Airflow Direction Control
Airflow direction can be individually adjusted for each air discharge outlet to deliver optimal air distribution.

Sensing Technology
Dual sensors and individual airflow direction control automatically provide optimal control of airflow.

Comfort

Unified square panels
Panel size is the same for all models. It is easy to maintain a neat appearance when multiple units are installed in the same room.

Optimal comfort and convenience assured by 3 air discharge modes

Switchable fan speed: 5 steps and Auto

Suitable for high ceilings
Even in spaces with high ceilings, a comfortable airflow is carried down to the floor level.

Cleanliness

Silver ion anti-bacterial drain pan
A built-in antibacterial treatment that uses silver ion in the drain pan prevents the growth of slime, bacteria, and mould that cause odours and clogging. (The lifespan of a silver ion cartridge depends on the usage environment, but should be changed once every two to three years.)

Non-flocking flaps
Flaps can be detached without use of tools. Condensation does not easily form and dirt does not cling to non-flocking flaps. They are easy to clean.

Filter has anti-mould and antibacterial treatment
Prevents mould and microorganisms growing out of the dust and moisture that adheres to the filters.

Quick and Easy Installation

Lightweight
All models can be installed without using a lifter.

Installable in tight ceiling spaces

Easy height adjustment
Each corner of the unit has an adjuster pocket that lets you easily adjust the unit’s suspended height.

Temporary placement of control box lid
Because the control box lid can be temporarily hung on the unit, there is no need to climb down the stepladder to retrieve it.

Installed in any direction
Since the orientation of the suction grille can be adjusted after installing, the direction of the suction grille lines can be unified when multiple units are installed.

Easy hanging
Washer fixing plates secure washers in place and prevent washers from falling for easy installation.

Easy removal of corner cover
It is possible to easily remove without use of screws or tools.

Ease in temporary hanging of decoration panel
In addition to the temporary hanging fixtures in 2 places normally used, corner part mounting fixtures in 4 places are provided.

Drain pump
Equipped as standard accessory with 850 mm lift.

Transparent drain socket

Easy Maintenance

Condition of the drain pan and drain water
Can be checked by removing the suction grille and drain plug.

24 mm diameter drain outlet
The drain outlet allows insertion of a finger or dental mirror for inspection of the internal cleanliness of the drain pan. Removal of the suction panel enables access.

Ultra long-life filter (option)

Low gas pressure detection

Auto grille panel (option)
Grille and air filter cleaning can be performed without need for a stepladder by lowering the grille.

 

DESCRIPTION

INCLUDED

  • BRC1E63 – DAI WIRED 7 DAY PROG CONTROL
  • FCA100CVMA – DAIKIN CASSETTE IND 10KW R32
  • RZAC100C2V1 – DAIKIN STANDARD OUT 10KW R32 1PH DRED
  • BYCQ125EAK – DAI R’FLOW CASS FASCIA – BLACK

BROCHURE

PCSAU2313-Daikin-SkyAir-Brochure_LR

Video

Reviews

There are no reviews yet.

Be the first to review “DAIKIN CS 10.0kW Standard Inverter Cassette System”

Your email address will not be published. Required fields are marked *