Mitsubishi Heavy Industries CS 6.0kW Four Way Compact Ceiling Cassette

$2,842.00

Mitsubishi Heavy Industries FDTC60VH

6.0 kW Four Way Compact Ceiling Cassette

Indoor: FDTC60VH | Outdoor: SRC60ZSXA-W

Panel:  TC-PSAE-5AW-E

5.6 kW Cooling | 6.7 kW Heating

3.23 Star Energy Rating

SPECIFICATIONS

CAPACITY 6.0kW
Set FDTC60VH
Indoor FDTC60VH
Outdoor SRC60ZSXA-W
Power Source (Outdoor Unit) 1 Phase 240V 50Hz

*Operation Data

Nominal Capacity (Range)

Cooling T1

kW

5.6 (1.1-6.3)
Heating H1 6.7 (0.6-6.7)
Heating H2 5.80
Power Consumption Cooling T1 1.73
Heating H1 2.14
Maximum Power Consumption 2.90
Running Current Cooling T1

A

7.6
Heating H1 9.4
Inrush Current, Maximum Current 5, 15
EER Cooling T1 3.23
COP Heating H1 3.13
Sound Power Level (JIS C9612) Outdoor

dB(A)

65

Sound Pressure Level (JIS C9612)

Indoor P-Hi:46 Hi:42 Me:38 Lo:31
Outdoor 54

External dimensions (HXWXD)

Indoor

mm

248x570x570
Panel 10X620X620 TC-PSAE-5AW-E (Honeycomb) / TC-PSAGE-5AW-E (Grid)
Outdoor 640×800(+71)x290
Net weight Indoor kg Unit 14 Panel 2.5
Outdoor 45
Airflow Cooling (Indoor) l/s P-Hi: 233 Hi: 200 Me: 167 Lo: 133
Heating (Indoor)

Installation Data

Refrigerant (R32) Quantity kg 1.3
Pre-Charged to Pipe m 15
Refrigerant Piping Liquid Line mm Ø6.35
Gas Line Ø12.7
Connection Method Flare Connection
Maximum Pipe Length (One Way) m 30
Max Vertical Height Diff. Between O.U. and I.U. 20 ( O.U. above I.U. ) / 20 ( O.U. below I.U. )
Controller RC-E5, RC-EXZ3A, RCH-E3 or RCN-TC-5AW-E2 / RCN-TC-5AW-E3 (Fine Snow)
Motion Sensor (Optional) LB-TC-5W-E
Demand Response (AS4755) Yes
Outdoor air temperature (upper, lower limits) Cooling oC -15 to 46
Heating -20 to 20

 

FEATURES

Energy Saving

SET TEMPERATURE AUTO RETURN

Program a preferred set temperature that the unit will return to each time it is switched on.Note: can only be enabled using the RC-EX3 wired controller.

 

HOME LEAVE OPERATION

This function ensures that when the room is unoccupied for long periods of time, the unit will maintain a moderate indoor temperature, avoiding extremely hot or cool temperatures and damage.Note: can only be enabled using the RC-EX3 wired controller.

 

AIR FLOW

VERTICAL AUTO SWING

The vertical louvres on your unit will move up and down continuously during operation. This function allows you to set the up/down swing position of the louver to your preferred operation angle

 

LOUVRE CONTROL SYSTEM

Set the upper and lower limit positions of each individual louvre, providing you with complete control over internal airflow.

AUTOMATIC FAN SPEED

The unit’s on-board microcomputer continuously monitors the room’s air temperature and adjusts the fan speed accordingly.

 

CLEAN AIR

AIR FILTER

Traps and removes air borne dust particles and other allergens, providing you with clean air throughout your home.

FILTER SIGN

Alerts you to when the filter needs to be cleaned.

OUTSIDE AIR INTAKE

Allocated outside air inlet connection available on indoor unit to provide fresh air into the room, avoiding the constant recycling of internal air.Disclaimer: Requires a separate outside air duct to be connected to indoor unit.

COMFORT & CONVENIENCE

AUTOMATIC OPERATION

Automatically selects the required heating or cooling function based on the current room conditions and set temperature.

PEAK-CUT TIMER

Set the capacity limit during certain periods of the day, minimising energy consumption during peak billing times, thus reducing operation costs.Note: can only be enabled using the RC-EX3 wired controller

FUNCTION SWITCH

From the six available functions on the unit, this function allows you to set two functions to operate automatically. (Note: this is not available when a centralised remote control is connected).Note: can only be enabled using the RC-EX3 wired controller

 

HI POWER OPERATION

Provides 15mins of boosted power to quickly heat or cool your home before returning to normal operation. Perfect for when you first turn on it the unit.Note: For FDE, FDT, FDTC, FDUA, and FDUM series can only be enabled using the RC-EX3 wired controller.

SILENT OPERATION

Set periods of time where the unit will operate with reduced noise levels, perfect for night time and an uninterrupted sleep.

WEEKLY TIMER

Set your unit to turn on and off at specific times for each day of the week to suit your needs.

SLEEP TIMER

Set a pre-determined amount of time between 30 and 240 mins that your unit will operate for before switching off.

MAINTENANCE

BUILT-IN DRAIN PUMP

The built-in drain pump allows greater flexibility with installation, offering a perfect solution for applications with limited space.

SELF-DIAGNOSTICS

In the unlikely event of a fault the internal microcomputer automatically runs a diagnostic of the system. This enables a service agent to quickly isolate and repair any issues.

DESCRIPTION

INCLUDED

  • TC-PSAGE-5AW-E – MHI 4W COMP CASS FASCIA FDTC
  • FDTC60VH – MHI 4W COMP CASS IDU R/C 6KW R32
  • SRC60ZSXA-W – MHI HWS AVANTI+ OUT 6KW

BROCHURE

MHIAA-Ceiling-Systems-Brochure-May-2023-WEB (1)

User-Manual-RC-E5-Controller-FDUA-FDUM-FDCA-FDT-FDTC-FDE-Series

User-Manual-RCH-E3-Controller-FDUA-FDUM-FDCA-FDT-FDTC-FDE-Series

Video

Reviews

There are no reviews yet.

Be the first to review “Mitsubishi Heavy Industries CS 6.0kW Four Way Compact Ceiling Cassette”

Your email address will not be published. Required fields are marked *

You may also like…