Mitsubishi Heavy Industries High Static SDR 14.0kW Ducted System

$5,323.00

Mitsubishi Heavy Industries FDUA140AVNXWVH

14.0kW High Static Ducted System | 1 Phase

Includes R32 | Splittable Indoor | max pipe length 100mtrs

Indoor FDUA140VH | Outdoor FDCA140VNX-W

Precharged: 30m
Max Pip length: 100m

14.0 kW Cooling | 16.0 kW Heating

3.48 Star Energy Rating

SPECIFICATIONS

CAPACITY 14.0KW
Set FDUA140AVNXWVH
Indoor FDUA140VH
Outdoor FDCA140VNX-W
Power Source (Outdoor Unit) 1 Phase 240V 50Hz
 

 

 

 

 

 

 

 

 

*Operation Data

 

Nominal Capacity Range

Cooling T1  

 

 

kW

14.0 (5.0-14.5)
Heating H1 16.0 (4.0-18.0)
Heating H2 15.50
 

Power Consumption

Cooling T1 4.02
Heating H1 4.19
Max Power Consumption 5.77
 

Running Current

Cooling T1  

A

17.8
Heating H1 18.6
Inrush Current, Maximum Current 5, 30
EER Cooling T1 3.48
COP Heating H1 3.82
Sound Power Level (JS C9612) Outdoor  

 

dB(A)

73
Sound Pressure Level (JS C9612) Indoor P-Hi:48 Hi:47 Me:43 Lo:38
Outdoor 54
 

External Dimensions (HXWXD)

Indoor  

mm

398x1450x930
Outdoor 1300x970x370
 

Net Weight

Indoor  

Kg

66
Outdoor 97
Supply Air Connection  

mm

298×1064
Return Air Connection 2 X Ø400
External Static Pressure (Max) Pa 150
Airflow Indoor (Cooling) l/s P-Hi:1000 Hi:867 

Me:733 Lo:600

Indoor (Heating)
 

Refrigerant (Type, Amount, Pre-charge Length)

Quantity kg (R32) 4.0
Pre Charged To Pipe 

Length

m 30
 

 

 

Installation Data

 

Refrigerant Piping

Liquid Line  

mm

Ø9.52
Gas Line Ø15.88
Connection Method Flare connection
Maximum Pipe Length (One Way)  

m

100
Max vertical height diff. between O.U. and I.U. 30 ( O.U. above I.U. ) / 15 ( O.U. below I.U. )
Controller RC-E5, RC-EXZ3A, RCH-E3 or RCN-KIT4-E2
Safety Pan (Optional) N/A
Motion Sensor (Optional) LB-KIT2
Demand response (AS4755) Yes
Outdoor air temperature (upper, lower limits) Cooling  

oC

-15 to 50
Heating -20 to 20

 

FEATURES

ENERGY SAVING

HOME LEAVE OPERATION

Maintains a moderate indoor temperature, avoiding extremely hot or cool temperatures. Suitable for when rooms are unoccupied for long periods of time.

SET TEMPERATURE AUTO RETURN

Program a preferred set temperature that the unit will return to each time it is switched on. Requires RC-EXZ3A wired controller.

ECONOMY MODE

Unit operates at slightly reduced capacity to reduce power consumption while maintaining a comfortable room temperature.

 

COMFORT & CONVENIENCE

AUTOMATIC OPERATION

Automatically selects the required heating or cooling function based on the current room conditions and set temperature.

DRY OPERATION

Reduces humidity by removing moisture from the air without affecting indoor temperature.

FUNCTION SWITCH

Set two functions to operate automatically. Requires RC-EXZ3A wired controller and no other central controller to be connected.

PEAK-CUT TIMER

Set the capacity limit during peak billing times, minimising energy consumption and reducing running costs. Requires RC-EXZ3A wired controller.

HI POWER OPERATION

Provides 15mins of boosted power to quickly heat or cool your home before returning to normal operation. Perfect for when you first turn on it the unit.

SILENT OPERATION

Set periods of time where the unit will operate with reduced noise levels, perfect for night time and an uninterrupted sleep.

WEEKLY TIMER

Set your unit to turn on and off at specific times for each day of the week to suit your needs.

SLEEP TIMER

Set a pre-determined amount of time between 30 and 240 mins that your unit will operate for before switching off.

ON/OFF TIMER

Set your unit to turn on and off once, at specific times, within a 24 hour period.

 

AIR FLOW

FILTER SIGN

Alerts you to when the filter needs to be cleaned.

OUTSIDE AIR INTAKE

Allocated outside air inlet connection available on indoor unit to provide fresh air into the room, avoiding the constant recycling of internal air. Requires separate outside air duct to be connected to indoor unit.

AUTOMATIC FAN SPEED

The unit’s on-board microcomputer continuously monitors the room’s air temperature and adjusts the fan speed accordingly.

 

MAINTENANCE

BUILT-IN DRAIN PUMP

The built-in drain pump allows greater flexibility with installation, offering a perfect solution for applications with limited space.

IMPROVED SERVICEABILITY

The fan unit (comprised of impeller and motor) is easily accessible from either the side or bottom of the unit and can be slid out for easy maintenance.

SELF-DIAGNOSTICS

In the unlikely event of a fault the internal microcomputer automatically runs a diagnostic of the system. This enables a service agent to quickly isolate and repair any issues.

DESCRIPTION

INCLUDED

  • FDCA140VNX-W – MHI DUC/CAS ODU 14KW R32 1PH
  • FDUA140VH – MHI H/STAT DUC IDU R/C 14KW NC R32

BROCHURE

Mitsubishi-Heavy-Industries-Ducted-System-Brochure

Video

Reviews

There are no reviews yet.

Be the first to review “Mitsubishi Heavy Industries High Static SDR 14.0kW Ducted System”

Your email address will not be published. Required fields are marked *

You may also like…