SPECIFICATIONS
| Technical Information | ||
| OUTDOOR MODEL | WRC-026CS | |
| INDOOR MODEL | WRE-026CS | |
| Nett (Rated) Capacity (kW) (AS/NZS3823.1.1) | Cooling (min – max) | 2.65 (1.00 – 3.50) |
| Heating (min – max) | 2.75 (1.40 – 4.00) | |
| Input Power (kW) (AS/NZS3823.1.1) | Cooling Rated | 0.45 |
| Heating Rated | 0.49 | |
| 1 EER Rated (AS/NZS3823.1.1)
2 COP Rated (AS/NZS3823.1.1) |
Cooling Rated | 5.89 |
| Heating Rated | 5.61 | |
| Star Rating (AS/NZS3823.1.1) Hot/Average/Cold | Cooling | 7 / 6.5 / 7 |
| Heating | 4 / 3.5 / 3 | |
| Power Supply – (V / Ph / Hz) | Outdoor | 220 – 240 V / 1Ph+N / 50Hz |
| Rated Load Amps (AS/NZS3823.1.1) | Cooling | 2.0 |
| Heating | 2.2 | |
| Full Load Amps (AS/NZS3823.1.1) | 9.5 | |
| Circuit Breaker Amps | 10.0 | |
| Suggested Minimum Mains Cable Size | 1.5mm2 | |
| Suggested Minimum Indoor to Outdoor Cable Size & Type | Size | 1.0mm2 |
| Type | 3 Core + Earth | |
| IP Rating | Outdoor | IP24 |
| Indoor | IP20 | |
| Moisture Removal (L/hr) | 1.6 | |
| Compressor | Inverter Rotary | |
| Refrigerant | R-32 | |
|
Airflow Range Indoor (l/s) |
Boost | 250 |
| High | 180 | |
| Medium | 120 | |
| Low | 100 | |
|
Outdoor Dimensions (mm) |
Depth | 333 |
| Height | 554 | |
| Width | 805 | |
|
Indoor Dimensions (mm) |
Depth | 225 |
| Height | 295 | |
| Width | 795 | |
| Nominal Weight (kgs) | Outdoor | 32.2 |
| Indoor | 10.3 | |
| 4 Indoor Sound Pressure Level (dBA) | (SI/Low / Med / High) | 24 / 30 / 32 / 38 |
| 4 Outdoor Sound Pressure Level (dBA) 1m | 52 | |
| 5 Outdoor Sound Power Level (dBA) | 57 | |
| Outdoor Operating Range (°C) | Cooling | -15°C to 60°C |
| Heating | -25°C to 30°C | |
| MEPS Certified | Yes | |

















Reviews