Mitsubishi Heavy Industries High Static SDR 12.5kW Ducted System

$4,807.00

Mitsubishi Heavy Industries FDUA125AVSXWVH

12.5kW High Static Ducted System | 3 Phase

Includes : Indoor FDUA125VH | Outdoor FDCA125VSX-W

Refrigerant R32 Weight: 4.0kg

Precharged: 30m

Max Pip length: 100m

12.5 kW Cooling | 14.0 kW Heating

3.26 Star Energy Rating

SPECIFICATIONS

CAPACITY 12.1KW
Set FDUA125VNPWVH
Indoor FDUA125VH
Outdoor FDC125VNP-W
Power Source (Outdoor Unit) 1 Phase 240V 50Hz
 

 

 

 

 

 

 

 

 

*Operation Data

 

Nominal Capacity Range

Cooling T1  

 

 

kW

12.1
Heating H1 12.1
Heating H2 14.20
 

Power Consumption

Cooling T1 3.83
Heating H1 3.68
Max Power Consumption 6.13
 

Running Current

Cooling T1  

A

17.0
Heating H1 16.3
Inrush Current, Maximum Current 5, 29
EER Cooling T1 3.26
COP Heating H1 3.80
Sound Power Level (JS C9612) Outdoor  

 

dB(A)

70
Sound Pressure Level (JS C9612) Indoor P-Hi:46 Hi:44 Me:42 Lo:38
Outdoor 54
 

External Dimensions (HXWXD)

Indoor  

mm

398x1150x650
Outdoor 845x970x370
 

Net Weight

Indoor  

Kg

52
Outdoor 73
Supply Air Connection  

mm

348×898
Return Air Connection 348×898
External Static Pressure (Max) Pa 200
Airflow Indoor (Cooling) l/s P-Hi:717 Hi:650

Me:600 Lo:500

Indoor (Heating)
 

Refrigerant (Type, Amount, Pre-charge Length)

Quantity kg (R32) 4.0
Pre Charged To Pipe

Length

m 30
 

 

 

Installation Data

 

Refrigerant Piping

Liquid Line  

mm

Ø9.52
Gas Line Ø15.88
Connection Method Flare connection
Maximum Pipe Length (One Way)  

m

100
Max vertical height diff. between O.U. and I.U. 30 ( O.U. above I.U. ) / 15 ( O.U. below I.U. )
Controller RC-E5, RC-EXZ3A, RCH-E3 or RCN-KIT4-E2
Safety Pan (Optional) UA-SP2-E
Motion Sensor (Optional) LB-KIT2
Demand response (AS4755) Yes
Outdoor air temperature (upper, lower limits) Cooling  

oC

-15 to 50
Heating -20 to 20

FEATURES

ENERGY SAVING

HOME LEAVE OPERATION

Maintains a moderate indoor temperature, avoiding extremely hot or cool temperatures. Suitable for when rooms are unoccupied for long periods of time.

SET TEMPERATURE AUTO RETURN

Program a preferred set temperature that the unit will return to each time it is switched on. Requires RC-EXZ3A wired controller.

ECONOMY MODE

Unit operates at slightly reduced capacity to reduce power consumption while maintaining a comfortable room temperature.

 

COMFORT & CONVENIENCE

AUTOMATIC OPERATION

Automatically selects the required heating or cooling function based on the current room conditions and set temperature.

DRY OPERATION

Reduces humidity by removing moisture from the air without affecting indoor temperature.

FUNCTION SWITCH

Set two functions to operate automatically. Requires RC-EXZ3A wired controller and no other central controller to be connected.

PEAK-CUT TIMER

Set the capacity limit during peak billing times, minimising energy consumption and reducing running costs. Requires RC-EXZ3A wired controller.

HI POWER OPERATION

Provides 15mins of boosted power to quickly heat or cool your home before returning to normal operation. Perfect for when you first turn on it the unit.

SILENT OPERATION

Set periods of time where the unit will operate with reduced noise levels, perfect for night time and an uninterrupted sleep.

WEEKLY TIMER

Set your unit to turn on and off at specific times for each day of the week to suit your needs.

SLEEP TIMER

Set a pre-determined amount of time between 30 and 240 mins that your unit will operate for before switching off.

ON/OFF TIMER

Set your unit to turn on and off once, at specific times, within a 24 hour period.

 

AIR FLOW

FILTER SIGN

Alerts you to when the filter needs to be cleaned.

OUTSIDE AIR INTAKE

Allocated outside air inlet connection available on indoor unit to provide fresh air into the room, avoiding the constant recycling of internal air. Requires separate outside air duct to be connected to indoor unit.

AUTOMATIC FAN SPEED

The unit’s on-board microcomputer continuously monitors the room’s air temperature and adjusts the fan speed accordingly.

 

MAINTENANCE

BUILT-IN DRAIN PUMP

The built-in drain pump allows greater flexibility with installation, offering a perfect solution for applications with limited space.

IMPROVED SERVICEABILITY

The fan unit (comprised of impeller and motor) is easily accessible from either the side or bottom of the unit and can be slid out for easy maintenance.

SELF-DIAGNOSTICS

In the unlikely event of a fault the internal microcomputer automatically runs a diagnostic of the system. This enables a service agent to quickly isolate and repair any issues.

DESCRIPTION

INCLUDED

  • FDC125VNP-W – MHI DUC ODU COMPACT 12.5KW R32 1PH
  • FDUA125VH – MHI H/STAT DUC IDU R/C 12.5KW NC R32

BROCHURE

Mitsubishi-Heavy-Industries-Ducted-System-Brochure

Video

Reviews

There are no reviews yet.

Be the first to review “Mitsubishi Heavy Industries High Static SDR 12.5kW Ducted System”

Your email address will not be published. Required fields are marked *

You may also like…